Research Article

[Retracted] Study on Thermal Performance Measurement and Construction of Passive Exterior Wall with Low Energy: Teaching and Laboratory Building of Shandong Jianzhu University

Table 5

Increment of mass humidity of insulation material inside the external wall after heating period.

Structural hierarchyTest pointHeating period in 2018, The allowed increment of mass humidity
East wallSouth wallNorth wall

Aerated concrete slabsPoint 26.4314.91.994
Graphite polystyrene platePoint 43.6617.73āˆ’2.3915