Research Article

Research on the Effect of Curing Temperature, Steel Fiber, and Admixture Content on Concrete Performance Based on Orthogonal Test in Cold Region

Table 1

The effect of concrete mixture temperature, steel fiber, and water reducing agent on slump.

NumberMixture temperature (°C)Steel fiber content (kg/m3)Water reducing agent content (kg/m3)Slump (mm)

1035023
2040440
30458248
4635433
56408231
664509
712358179
81240011
91245448