Research Article
Fatigue Failure Analysis of a Gear in Automobile Engine Coolant Pump
Figure 7
(a) Specimen 3 microstructure shows the finely tempered martensite in the case. (b) Specimen 3 microstructure reveals low carbon martensite in the core. (c) Microhardness traverse survey graph.
(a) |
(b) |
(c) |