Research Article
Investigation on Corrosion Behaviour of LM25-SiCp Composite Using Taguchi Method
Table 3
Design of experiments using Taguchi method and response (weight loss and corrosion rate).
| Sl. No | No of hours specimens dipped in 3% NaCl. | % Vol of SiCp | Aging at 170°C for hrs. | Weight loss “gm.” | Corrosion rate “mpy” |
| 1 | 144 | 10 | 8 | 0.002 | 1.772 | 2 | 144 | 15 | 16 | 0.003 | 1.329 | 3 | 144 | 20 | 24 | 0.003 | 2.658 | 4 | 288 | 10 | 16 | 0.003 | 1.329 | 5 | 288 | 15 | 24 | 0.004 | 1.772 | 6 | 288 | 20 | 8 | 0.006 | 0.886 | 7 | 432 | 10 | 24 | 0.005 | 2.215 | 8 | 432 | 15 | 8 | 0.004 | 1.772 | 9 | 432 | 20 | 16 | 0.003 | 1.329 |
| | | | Min | 0.002 | 0.886 | | | | Max | 0.006 | 2.658 |
|
|