Research Article

Investigation on Corrosion Behaviour of LM25-SiCp Composite Using Taguchi Method

Table 8

ANOVA test results on GRG.

SourceDfAdj. SSAdj. MSF-value value% Contribution

 No of hours specimens dipped in 3% NaCl20.2326390.1163190.920.02135.3
 % vol of SiCp20.2534720.1267360.010.05638.42
Aging at 170 for hours20.1701390.0850690.670.05925.78
Error20.0034720.0017360.5