Research Article

Investigation on Corrosion Behaviour of LM25-SiCp Composite Using Taguchi Method

Table 9

Result of conformation experiments.

Sl. NoInitial valueInitial testing factorOptimal parameters
PredictedExpected

1Combination of testingA2B3C1A1B3C2A1B3C2
2Corrosion rate “mpy”0.8860.89810.9122
3Weight loss “mg”0.0020.01220.0221
4GRG1.1250.8891.1221