Gas seal detection of tubular string thread in domestic gas storage.
| Name of gas storage | Type of string | Size of string (mm) | Steel grade of string | Type of thread | Number of test buckles | Number of leakage buckles | Passing rate (%) |
| XN | Tubing | 114.3 | 4 ½ VM80S + 3 ½ N80EUE/TP90S | VAM-TOP | 239 | 1 | 99.6 | Intermediate casing | 244.5 | TP95S | TPCQ | 369 | 6 | 98.4 | 339.7 | 292 | 8 | 97.3 | Suspension casing | 177.8 | TP95S | TPCQ | 140 | 0 | 100 | 244.5 | 221 | 5 | 97.7 | Tie-back casing | 177.8 | TP95S | TPCQ | 302 | 6 | 98.0 | 206.4 | VM95SS | VAM-FJL | 16 | 1 | 93.8 | 244.5 | TP95S | TPCQ | 290 | 12 | 95.9 |
| XB | Production casing | 177.8 | VM125HC | VAM-TOP | 382 | 24 | 93.7 | Suspension liner | 139.7 | HP1–13Cr110 | BEAR |
| DL | Production casing | 177.8 | N80 + L80 | BGC | 1711 | 14 | 99.2 | Intermediate casing | 244.5 | N80 | 1300 | 15 | 98.8 |
| DG | Intermediate casing | 273.1 | N80 | TPCQ | 837 | 1 | 99.9 | Suspension liner | 177.8 | P110 | 320 | 0 | 100 | Tie-back casing | 760 | 0 | 100 |
| SB | Suspension liner | 177.8 | P110 | BGC | 13 | 1 | 92.3 | Tie-back casing |
| CQ | Casing | 177.8 | 95S + TN110 Cr13S | TSH-3SB | 350 | 20 | 94.3 | 241.3 | 321 | 13 | 96.0 |
|
|