Research Article

Pharmaceutical Effluent Treatment Using Multi-effect Evaporator Process

Table 2

Comparison of pharma effluent treatment.

S. no.ParametersRaw combined effluentConventional methodNovel treatment method
Stage 1 air strippingStage 2 multi-effect evaporator
ValuesRemoval efficiencyValuesRemoval efficiency

1.pH7.57.6—7.68—
2.TSS, mg/l2800208925.39%105740485.57%
3.TDS, mg/l15300149682.17%7971215785.90%
4.BOD, mg/l8500376555.70%244357993.19%
5.COD, mg/l265001069559.64%9000495081.32%
6.TKN, mg/l80048439.5%32720474.5%