Research Article

Strain Measuring of Composite Grid Using Digital Image Correlation

Table 4

Young’s modulus comparison of BFRP-2.

Young’s modulus (MPa)Error (%)

DICLinear regression457890.00

Strain gaugeASTM44880−2.03
ACIN.AN.A
Linear regression44032−3.99

The data were not available because the strain gauge broke before the test reached 50% of the maximum load, which does not provide enough data for calculation.