Existing flexural strength estimate models use different standard codes.
| Measured value | IS 456-2000 [27]Fs = 0.7√Fc | ACI-363, 2008 [23]Fs = 0.94√Fc | CSA 2010 [24]Fs = 0.6√Fc | NZS-3101,2017 [25]Fs = 0.8√Fc |
| 2.81 | 3.28 | 4.22 | 2.81 | 3.75 | 2.92 | 3.36 | 4.32 | 2.88 | 3.84 | 2.98 | 3.40 | 4.38 | 2.92 | 3.89 | 2.95 | 3.44 | 4.40 | 2.95 | 3.93 | 2.80 | 3.30 | 4.25 | 2.83 | 3.78 | 2.78 | 3.27 | 4.21 | 2.80 | 3.74 |
|
|