Research Article

Adaptive Control of the Atmospheric Plasma Spray Process for Functionally Graded Thermal Barrier Coatings

Table 3

Values of the coefficients of the response functions for the mean temperature in equation (21). Here, “—” means the corresponding variable does not appear in the response function.

Single powder injection using NiCrAlYSingle powder injection using ZrO2
Number of samples100200300100200300

Intercept ()0.670.640.730.380.750.79
−0.38−0.47−0.35−0.43−0.35−0.47
1.511.051.001.160.540.76
0.190.470.230.560.420.18
−0.72−0.52−0.57
0.210.0650.002
−0.06−0.36−0.42
0.190.030.06
0.470.490.44−0.230.260.27
0.480.670.370.480.660.71
−0.290.0120.007
−0.34−0.37−0.27
0.030.060.06
−0.30−0.47−0.56
0.13−0.170.070.070.100.04
0.310.370.41
−0.130.030.12
−0.020.240.23
0.400.050.10
0.300.120.12
0.320.530.33
0.0090.010.005
0.210.430.55
0.250.090.12
0.030.040.07
−0.19−0.38−0.29−0.12−0.36−0.39
−1.08−0.80−0.87−0.36−0.38−0.57
−0.25−0.56−0.32−0.43−0.45−0.35
0.14−0.18−0.19
0.03−0.12−0.19
−0.31−0.04−0.13
−0.17−0.12−0.19

Regression coefficient0.970.970.970.970.970.97