Adaptive Control of the Atmospheric Plasma Spray Process for Functionally Graded Thermal Barrier Coatings
Table 3
Values of the coefficients of the response functions for the mean temperature in equation (21). Here, “—” means the corresponding variable does not appear in the response function.
Single powder injection using NiCrAlY
Single powder injection using ZrO2
Number of samples
100
200
300
100
200
300
Intercept ()
0.67
0.64
0.73
0.38
0.75
0.79
−0.38
−0.47
−0.35
−0.43
−0.35
−0.47
1.51
1.05
1.00
1.16
0.54
0.76
0.19
0.47
0.23
0.56
0.42
0.18
−0.72
−0.52
−0.57
—
—
—
−0.21
−0.065
0.002
—
—
—
—
—
—
−0.06
−0.36
−0.42
—
—
—
0.19
−0.03
−0.06
0.47
0.49
0.44
−0.23
0.26
0.27
0.48
0.67
0.37
0.48
0.66
0.71
−0.29
−0.012
0.007
—
—
—
−0.34
−0.37
−0.27
—
—
—
—
—
—
0.03
−0.06
0.06
—
—
—
−0.30
−0.47
−0.56
−0.13
−0.17
0.07
−0.07
−0.10
0.04
0.31
0.37
0.41
—
—
—
−0.13
−0.03
−0.12
—
—
—
—
—
—
−0.02
0.24
0.23
—
—
—
−0.40
−0.05
−0.10
0.30
0.12
0.12
—
—
—
0.32
0.53
0.33
—
—
—
—
—
—
−0.009
−0.01
0.005
—
—
—
0.21
0.43
0.55
0.25
−0.09
0.12
—
—
—
—
—
—
−0.03
−0.04
0.07
−0.19
−0.38
−0.29
−0.12
−0.36
−0.39
−1.08
−0.80
−0.87
−0.36
−0.38
−0.57
−0.25
−0.56
−0.32
−0.43
−0.45
−0.35
−0.14
−0.18
−0.19
—
—
—
−0.03
−0.12
−0.19
—
—
—
—
—
—
−0.31
−0.04
−0.13
—
—
—
−0.17
−0.12
−0.19
Regression coefficient
0.97
0.97
0.97
0.97
0.97
0.97
The values in bold numbers mean that their p values (not listed here) are less than 0.05, signifying their high influence.