Research Article
Study on the Testing Method of Relaxation Modulus under Spherical Indenter Loading
Table 1
Detailed comparison of 10 μm/s data and 100 μm/s data.
| Time/t | K value at 10 μm/s | K value at 100 μm/s | Relative error |
| 0.1 | 227968.1 | 216928.8 | 5.1% | 0.2 | 622540.7 | 682112.1 | 8.7% | 0.3 | 1184720 | 1285293 | 7.8% | 0.4 | 1781059 | 1946338 | 8.5% | 0.5 | 2530636 | 2646279 | 4.4% | 0.6 | 3315232 | 3386787 | 2.1% | 0.7 | 3945132 | 4160789 | 5.2% | 0.8 | 4806653 | 4944463 | 2.8% | 0.9 | 5672778 | 5739238 | 1.2% | 1 | 6677519 | 6554161 | 1.9% | 1.2 | 8525749 | 8248885 | 3.4% | 1.6 | 13048826 | 11757252 | 11.0% | 2 | 18278834 | 15442148 | 18.4% | 2.5 | 25466177 | 20192976 | 26.1% | 3.2 | 36753000 | 27055366 | 35.8% | 4 | 50715558 | 35114323 | 44.4% | 5 | 69684198 | 45933600 | 51.7% | 6.4 | 98303069 | 62866124 | 56.4% | 8 | 1.33 E + 08 | 84120171 | 58.7% | 10 | 1.8 E + 08 | 1.13 E + 08 | 59.5% |
|
|