Research Article

Study on the Testing Method of Relaxation Modulus under Spherical Indenter Loading

Table 1

Detailed comparison of 10 μm/s data and 100 μm/s data.

Time/tK value at 10 μm/sK value at 100 μm/sRelative error

0.1227968.1216928.85.1%
0.2622540.7682112.18.7%
0.3118472012852937.8%
0.4178105919463388.5%
0.5253063626462794.4%
0.6331523233867872.1%
0.7394513241607895.2%
0.8480665349444632.8%
0.9567277857392381.2%
1667751965541611.9%
1.2852574982488853.4%
1.6130488261175725211.0%
2182788341544214818.4%
2.5254661772019297626.1%
3.2367530002705536635.8%
4507155583511432344.4%
5696841984593360051.7%
6.4983030696286612456.4%
81.33 E + 088412017158.7%
101.8 E + 081.13 E + 0859.5%