Research Article

Study on the Testing Method of Relaxation Modulus under Spherical Indenter Loading

Table 2

Detailed comparison of 100 μm/s data and 1000 μm/s data.

Time/tK value at 100 μm/sK value at 1000 μm/sRelative error

0.0217410.9217942.73.0%
0.0453091.6166087.8619.7%
0.0699727.3117650.215.2%
0.08158025.5170811.57.5%
0.1216928.8224635.73.4%
0.2682112.1535817.427.3%
0.31285293863086.548.9%
0.41946338119182263.3%
0.52646279154614671.2%
0.63386787191867876.5%
0.74160789232400079.0%
0.84944463276431578.9%
0.95739238321627478.4%
16554161369414277.4%