Research Article

A GPR-Based Test Study on the Influencing Factors of the Dielectric Constant of Cement-Stabilized Macadam Bases

Table 3

Relationship between the dielectric constant and strength of CSMB specimens.

Compaction degree (%)Average compressive strength (MPa)Average dielectric constantCoefficient of determinationFitted function

Fine923.410866.965930.98779
943.576457.392900.89631
964.281757.334880.90873
984.761558.081760.95765
1005.691279.550400.98272

Coarse923.856197.536080.97117
944.044657.893990.95968
964.485338.242180.90271
984.999778.989020.93418
1005.9531810.008610.99453