Research Article

A GPR-Based Test Study on the Influencing Factors of the Dielectric Constant of Cement-Stabilized Macadam Bases

Table 6

Summary of the test results and calculated results by the comprehensive equation of dielectric constant.

No.CalculatedTestError (test-calculated)No.CalculatedTestError (test-calculated)

17.62637.75880.1325319.48529.3001−0.1851
27.24597.1016−0.1443329.10488.665−0.4398
36.86556.92080.0553338.72448.3424−0.3820
46.48506.80570.3207348.34407.9857−0.3583
56.10466.68110.5765357.96357.7758−0.1877
65.72426.52770.8035367.58317.3842−0.1989
78.29538.61830.3230379.41128.9784−0.4328
87.91497.7243−0.1906389.03088.4951−0.5357
97.53457.419−0.1155398.65038.2843−0.3660
107.15407.28280.1288408.26997.8525−0.4174
116.77367.18380.4102417.88957.6565−0.2330
126.39326.98830.5951427.50917.2237−0.2854
138.22138.51530.29404310.080210.18260.1024
147.84097.7825−0.0584449.69989.6602−0.0396
157.46047.2677−0.1927459.31939.2539−0.0654
167.08007.08460.0046468.93898.7755−0.1634
176.69966.91530.2157478.55858.3131−0.2454
186.31926.7920.4728488.17817.7527−0.4254
198.89039.06310.17284910.006211.0060.9998
208.50998.2387−0.2712509.625710.25920.6335
218.12947.7721−0.3573519.24539.88180.6365
227.74907.6402−0.1088528.86499.12110.2562
237.36867.47570.1071538.48458.80370.3192
246.98827.17410.1859548.10408.23060.1266
258.81628.4092−0.40705510.675211.57230.8971
268.43587.5303−0.90555610.294710.88440.5897
278.05547.2155−0.8399579.914310.37930.4650
287.67507.0899−0.5851589.53399.89950.3656
297.29456.9761−0.3184599.15359.0737−0.0798
306.91416.7883−0.1258608.77308.2445−0.5285