Research Article

Experimental Study and Microscopic Analysis on Frost Resistance of Iron Ore Tailings Recycled Aggregate Concrete

Table 4

Mixed proportions of concrete.

KingsCement (kg/m3)Natural sand (kg/m3)IOT (kg/m3)Air-entrained agent (A-EA) (%)NCA (kg/m3)RCA (kg/m3)Water (kg/m3)

RAC0-IOT0512.50504.750.000.021177.750.00205.00
RAC0-IOT3512.50353.33151.430.021177.750.00205.00
RAC0-IOT5512.50252.38252.380.021177.750.00205.00
RAC0-IOT7512.50151.43353.330.021177.750.00205.00
RAC3-IOT0512.50504.750.000.02824.43353.33205.00
RAC3-IOT3512.50353.33151.430.02824.43353.33205.00
RAC3-IOT5512.50252.38252.380.02824.43353.33205.00
RAC3-IOT7512.50151.43353.330.02824.43353.33205.00
RAC5-IOT0512.50504.750.000.02588.88588.88205.00
RAC5-IOT3512.50353.33151.430.02588.88588.88205.00
RAC5-IOT5512.50252.38252.380.02588.88588.88205.00
RAC5-IOT7512.50151.43353.330.02588.88588.88205.00
RAC7-IOT0512.50504.750.000.02353.33824.43205.00
RAC7-IOT3512.50353.33151.430.02353.33824.43205.00
RAC7-IOT5512.50252.38252.380.02353.33824.43205.00
RAC7-IOT7512.50151.43353.330.02353.33824.43205.00