Research Article

A New Electrohydraulic Hybrid Energy-Saving System Used on the Reversible Rolling Mills

Table 6

Basic parameters of the energy recovery model of reversible rolling mill.

NameParametersValue

Three-phase permanent magnet synchronous motorRated power (kW)600
Rated speed (rpm)600
Moment of inertia GD2 (kg·m2)174

RollMoment of inertia (kg·m2)1.091

Axial plunger variable motorDisplacement (mL/r)80
Volumetric efficiency0.97
Mechanical efficiency0.90

High-pressure accumulatorNominal volume (L)40
Nominal pressure (MPa)31.5
Preinflation pressure (MPa)18

Low-pressure accumulatorNominal volume (L)40
Nominal pressure (MPa)10
Preinflation pressure (MPa)2