Research Article

Tribological Behavior of Ni-P Electroless Coating of Inconel 625 with Multiwall Nano Carbon Tubes

Table 4

Predicted vs. experimental trail values.

S. noActualPredictedPercentage error (%)

10.00090.00090.00
20.00090.00090.00
30.00090.00090.00
40.00090.00090.00
50.00090.000812.50
60.00070.000812.50
70.00090.00090.00
80.00080.00080.00
90.00070.00070.00
100.00110.00110.00
110.00110.00110.00
120.00110.00110.00
130.00120.00119.09
140.00110.00110.00
150.00090.001010.00
160.00110.00110.00
170.00100.00100.00
180.00080.000911.11
190.00130.00147.14
200.00130.00130.00
210.00130.00128.33
220.00140.00140.00
230.00120.00137.69
240.00110.00128.33
250.00140.00140.00
260.00120.00120.00
270.00110.00110.00