Research Article
[Retracted] Influence of Metallic Particles on Properties of Aluminium Composites through Taguchi Technique
Table 8
ANOVA for wear loss, employing adjusted SS for tests.
| Source | DoF | SS | Adjusted sum of squares | Adjusted mean of squares | F-ratio | -value | % of contribution |
| A | 2 | 0.000154 | 0.000154 | 0.000077 | 41.23 | 0.001 | 32.835 | B | 2 | 0.000119 | 0.000119 | 0.000059 | 37.57 | 0.0002 | 27.624 | C | 2 | 0.000102 | 0.000102 | 0.000053 | 28.13 | 0.0002 | 24.135 | D | 2 | 0.000017 | 0.000017 | 0.000009 | 6.42 | 0.051 | 4.931 | A × B | 4 | 0.000011 | 0.000011 | 0.000005 | 3.94 | 0.159 | 3.598 | A × C | 4 | 0.000005 | 0.000005 | 0.000003 | 0.32 | 0.830 | −2.837 | B × C | 4 | 0.000002 | 0.000002 | 0.000002 | 0.41 | 0.869 | −2.162 | Error | 6 | 0.000012 | 0.000012 | | | | 11.876 | Total | 26 | 0.00043 | 0.00043 | | | | 100 |
|
|