DOE experiment parameters, RSD results, and CI results.

S. no.Impeller rotation per minuteBlending time (min)Fill levels (%)Relative standard deviationCarr index

11601305.3419.77
21605302.920.33
31605702.9921.41
41203503.8219.68
58057018.518.89
61203504.1219.78
71203504.4419.51
88053016.818.83
91601705.8820.12
108017021.318.89
118013019.2318.62