Research Article

Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures

Figure 1

Fluoroscopic (a) dorsal tangential and (b) traditional lateral views of third screw from the radial aspect of the plate with a 4 mm dorsal cortex protrusion, as presented during survey analysis. Yellow arrows denote the protruding screw.
(a)
(b)