Research Article
Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures
Table 3
Overall accuracy based on imaging technique and screw position and degree of prominence.
| | 1 (radial styloid) | 2 | 3 | 4 (ulnar corner) |
| DT 0 mm | 84.6% (1 image) | | | | Lat 0 mm | 85.7% (1 image) | | | | DT 2 mm | 78.1 ± 4.4% | 100% (1 image) | 79.5 ± 11.4% | 50 ± 44.2% | Lat 2 mm | 5.9 ± 8.3% | 35.6 ± 49.01% | 18.9% (1 image) | 61.1% (1 image) | DT 4 mm | 93.45 ± 6.3% | 100% (1 image) | 60 ± 56.6% | 65.8 ± 40.0% | Lat 4 mm | 13.0 ± 1.8% | 75 ± 35.4% | 100% (1 image) | 83.3% (1 image) | DT 6 mm | 96.9 ± 4.4% | 100% (1 image) | 75.2 ± 26.8% | 78.9 ± 3.4% | Lat 6 mm | 49.4 ± 61.5% | 97.6 ± 4.1% | 100% (1 image) | 50.8 ± 61.7% |
|
|