Research Article

An Ameliorated Small-Signal Model Parameter Extraction Method for GaN HEMTs up to 110 GHz with Short-Test Structure

Table 1

Results of parasitic parameter extraction.

ParametersUnitsValues

CpgdfF0.0046
CpgfF18.1273
CpdfF17.2525
RdΩ4.0713
Ω2.2850
Ω45.54
RpdΩ20.83
RsΩ0.255
LdpH117.332
pH119.605
LspH47.663