Research Article

Bond Performance of Carbon Fiber-Reinforced Polymer Bar with Dual Functions of Reinforcement and Cathodic Protection for Reinforced Concrete Structures

Table 4

Results of the polarization resistance measurements at 120 days of ICCP application.

Specimen No.ICCP Current density (mA/m2)Linear polarization resistance (kOhms)Corrosion current density (μA/cm2)Corrosion stage

I-0-RF00.3671.28High
I-5-4M53.4090.13Low
I-20-4M200.9630.48Low
I-50-4M503.8840.12Low
I-100-4M1003.2790.14Low