Research Article

Analysis of the Multiwalled Carbon Nanotubes Reinforced Polymethyl Methacrylate Bone Cement’s Characteristics and In Vitro Bioactivity to Prolong Its Functionality in Orthopedic Application

Table 3

Percentage variation in setting time and contact angle.

Bone cement samplesSetting time %↑Contact angle %↓
InitialFinal

BC10.820.491.25↓
BC21.320.982.95↓
BC32.472.125.85↓
BC42.972.947.45↓