Research Article

Possibility of Removing Pb and Cd from Polluted Water by Modified Fly Ash

Table 2

Kinetic model fitting parameters for Cd2+ and Pb2+ adsorption.

Pseudo-first-orderPseudo-second-order
Metal ions (mg/g) (mg/g) (1/min) (mg/g) (g/mg 1/min)

Cd2+72.5932.220.00820.833678.740.00240.9928
Pb2+122.7465.750.0130.8366115.530.00130.9925