Research Article
Treatability Studies on the Optimization of Ozone and Carbon Dosages for the Effective Removal of Contaminants from Secondary Treated Effluent
Table 1
Design quality parameters of the advanced treatment scheme.
| Specification | Pressure sand filter | Ultrafiltration | Granular activated carbon |
| Diameter | 250 mm | — | 250 mm | Height | 1350 mm | — | 1350 mm | Media | Sand & pebbles | Hydrophilic membrane | Sand, activated carbon | Pressure | 0.24 MPa | ≤0.15 MPa | 0.24 MPa | Operating flow | — | 250 LPH | — | Permeate flow | — | 200 LPH | — | Surface area | — | — | 1100 m2/g | pH | — | 1-10 | — | Operating temperature (°C) | — | 5-45 | — |
|
|