Review Article

Review of the Pressure Swing Adsorption Process for the Production of Biofuels and Medical Oxygen: Separation and Purification Technology

Table 9

Works reported on the different configurations of PSA processes for purification of biohydrogen.

ReferenceExperimental/simulatedPSA cyclesPressure swing (kPa)Bed regeneration time (min)Hydrogen feed (% molar fraction)

[55]Simulated2 beds500 to 50579
10 steps
[67]Simulated10 beds(1300-1200) to 2062.57
5 steps
[56]Experimental2 beds350 to 1007.567, 68, 78, and 81
4 steps
[57]Experimental2 beds350 to 1005.867, 68, and 78
4 steps
[58]Simulated6 beds1100 to 1006.670
9 and 12 steps
[68]Experimental4 beds(1400-1600) to (131-50)55
8 steps
[59]Simulated4, 6, 8, and 10 beds(3450-1730) to 1004.615
4, 6, 8, and 10 steps
[60]Simulated4 beds1600 to 10025, 50, and 75
7 steps
[69]Experimental2 beds(1000-4000) to 1000.850
5 steps
[70]Experimental8 beds3500 to 100488.75
12 steps
[71]Experimental2 and 4 beds(3000-3500) to 1105 and 6.388
6 and 10 steps