Works reported on the different configurations of PSA processes for purification of biohydrogen.
| Reference | Experimental/simulated | PSA cycles | Pressure swing (kPa) | Bed regeneration time (min) | Hydrogen feed (% molar fraction) |
| [55] | Simulated | 2 beds | 500 to 50 | 5 | 79 | 10 steps | [67] | Simulated | 10 beds | (1300-1200) to 20 | — | 62.57 | 5 steps | [56] | Experimental | 2 beds | 350 to 100 | 7.5 | 67, 68, 78, and 81 | 4 steps | | [57] | Experimental | 2 beds | 350 to 100 | 5.8 | 67, 68, and 78 | 4 steps | [58] | Simulated | 6 beds | 1100 to 100 | 6.6 | 70 | 9 and 12 steps | [68] | Experimental | 4 beds | (1400-1600) to (131-50) | — | 55 | 8 steps | [59] | Simulated | 4, 6, 8, and 10 beds | (3450-1730) to 100 | 4.6 | 15 | 4, 6, 8, and 10 steps | [60] | Simulated | 4 beds | 1600 to 100 | — | 25, 50, and 75 | 7 steps | | [69] | Experimental | 2 beds | (1000-4000) to 100 | 0.8 | 50 | 5 steps | [70] | Experimental | 8 beds | 3500 to 100 | 4 | 88.75 | 12 steps | [71] | Experimental | 2 and 4 beds | (3000-3500) to 110 | 5 and 6.3 | 88 | 6 and 10 steps |
|
|