Research Article

Garlic Peel Surface Modification and Fixed-Bed Column Investigations towards Crystal Violet Dye

Table 3

Parameters and constants of the Thomas model for the removal of CV by MGP.

Parameter (ml/min mg) (mg/g)

Flow rate of solution (ml/min)32.1x10-345.70.989
52.4x10-332.80.979
72.6x10-329.70.971

Adsorbent depth (cm)12.1x10-345.70.989
21.9x10-369.90.991
31.6x10-397.40.993

Preliminary concentration (mg l-1)1001.6x10-397.40.993
2001.9x10-377.50.981
3002.6x10-458.80.975