Research Article
Comparison of Bioabsorbable Magnesium versus Titanium Screw Fixation for Modified Distal Chevron Osteotomy in Hallux Valgus
Table 3
Summary of functional results.
| | Preop VAS | Final VAS | Significance |
| Magnesium | 4.7 ± 2.1 | 1.9 ± 1.9 | .000 |
| Titanium | 5.1 ± 1.9 | 2.0 ± 0.5 | .000 |
| Significance | 0.620 | 0.535 | |
| | Preop AOFAS-MTP-IP | Final AOFAS-MTP-IP | |
| Magnesium | 71.2 ± 8.3 | 84.1 ± 9.6 | .000 |
| Titanium | 69.2 ± 9.4 | 83.0 ± 11.7 | .000 |
| Significance | 0.505 | 0.764 | |
| | Preop ROM | Final ROM | |
| | N M S | N M S | |
| Magnesium | 10 7 0 | 4 10 3 | .0290 |
| Titanium | 12 5 0 | 2 12 3 | .0100 |
| Significance | 0.360 | 0.654 | |
|
|
MTP joint ROM (dorsiflexion plus plantar flexion), N: normal (>75°), M: minimal restriction (30°-74°), and S: severe restriction (<30°).
|