Research Article
Optimized Cylindrical Diffuser Powers for Interstitial PDT Breast Cancer Treatment Planning: A Simulation Study
| Node number | Tumor diameter (cm) | Total slices in the node | Power of the central fiber reaches up to slice | Power of the central fiber (mW/cm) | Power of surrounding fibers (mW/cm) | Target dose reaches up to volume % | Length of the surrounding diffusers (cm) | The distance (cm) |
| 1 | 0.5 | 5 | All | 65 | — | 100 | 0.3999 | — | 2 | 1 | 10 | All | 70 | — | 100 | 0.7998 | — | 3 | 1.5 | 15 | 4 | 65 | 15 | 90 | 1.1998 | 0.4502 | 4 | 2 | 20 | 2 | 65 | 35 | 95 | 1.5997 | 0.6002 | 5 | 2.5 | 25 | 2 | 65 | 55 | 90 | 1.9996 | 0.7503 | 6 | 3 | 30 | 2 | 70 | 65 | 81 | 2.3995 | 0.9003 | 7 | 3.5 | 35 | 2 | 65 | 95 | 82 | 2.7994 | 1.0504 | 8 | 4 | 40 | 4 | 70 | 120 | 79 | 3.1994 | 1.2004 | 9 | 4.5 | 45 | 2 | 75 | 175 | 81 | 3.5993 | 1.3505 | 10 | 5 | 50 | 2 | 80 | 215 | 79 | 3.9992 | 1.5005 |
|
|