Research Article

[Retracted] The Effect on the Fracture Healing following Femoral Neck Shortening after Osteoporotic Femoral Neck Fracture Treated with Internal Fixation: Finite Element Analysis

Table 1

The material parameters of femoral neck shortening model after cannulated screw fixation.

Structural regionModulus of elasticity (MPa)Poisson’s ratio

Cortical bone of femur16 8000.30
Cancellous bone of femur6200.29
Acetabular cartilage100.40
Cannulated screw (Ti6Al4VELI)110 0000.33