Research Article

The Challenge of Using an Antigen Test as a Screening Tool for SARS-CoV-2 Infection in an Emergency Department: Experience of a Tertiary Care Hospital in Southern Italy

Table 3

Comparison of the results from the CLEIA antigen test and the RT-qPCR test for SARS-CoV-2.

RT-qPCR+
(%)
RT-qPCR-
(%)
Total
(%)

CLEIA + (≥1.34 pg/mL)205 (91.9%)18 (8.1%)223 (24.5%)
CLEIA - (<1.34 pg/mL)11 (1.6%)677 (98.4%)688 (75.5%)
Total216 (23.7%)695 (76.3%)911

RT-qPCR: Real-time Reverse transcription-Polymerase Chain Reaction; CLEIA: chemiluminescence enzyme immunoassay.