Research Article
Changes in Coronal Alignment of the Knee Joint after Supramalleolar Osteotomy
Table 1
Inter- and intraobserver reliability of the radiologic parameters.
| | Correction angle | Interobserver reliability | Intraobserver reliability |
| | Ankle | | Tibiotalar angle | 0.94 (0.87 to 0.99) | 0.93 (0.86 to 0.99) | | Talar tilt angle | 0.91 (0.81 to 0.97) | 0.91 (0.79 to 0.97) | | LDTA | 0.92 (0.87 to 0.97) | 0.91 (0.79 to 0.97) | | Knee | | MPTA | 0.92 (0.87 to 0.97) | 0.94 (0.87 to 0.99) | | mJSW | 0.95 (0.87 to 0.99) | 0.92 (0.87 to 0.97) | | lJSW | 0.95 (0.88 to 0.99) | 0.93 (0.86 to 0.99) | | JLCA | 0.93 (0.86 to 0.99) | 0.90 (0.79 to 0.97) | | Mechanical axis | | HKA angle | 0.90 (0.79 to 0.97) | 0.91 (0.79 to 0.97) | | MADA | 0.88 (0.77 to 0.96) | 0.89 (0.76 to 0.98) |
|
|
HKA: hip-knee-ankle; JLCA: joint line convergence angle; lJSW: lateral joint space widths; MADA: mechanical axis deviation angle; mJSW: medial joint space widths; MPTA: medial proximal tibial angle.
|