A Mathematical Method to Adjust MLC Leaf End Position for Accurate Dose Calculation in Carbon Ion Beam Radiation Therapy Treatment Planning System Table 3 The MLC leaf end offset correction and secondary radiation equivalent dose for different materials of 400 MeV/n carbon ion beam at different field sizes.
Field size/2 (cm) 1 cm2 2 cm2 3 cm2 4 cm2 5 cm2 6 cm2 7 cm2 8 cm2 9 cm2 Secondary radiation equivalent dose (10-4 Sv) Offset correction (mm) W100 -0.05101 -0.12479 -0.19793 -0.27667 -0.34578 -0.36887 -0.43788 -0.50684 -0.57572 4.046 7 W90 Cu10 -0.07208 -0.14874 -0.2208 -0.30202 -0.36022 -0.44136 -0.49946 -0.58049 -0.64328 3.8475 W50 Cu50 -0.08587 -0.17915 -0.25441 -0.33522 -0.41607 -0.51409 -0.61493 -0.68951 -0.76274 3.613 8 Fe100 -0.10829 -0.21594 -0.32435 -0.43254 -0.54067 -0.65289 -0.7421 -0.8669 -0.9768 2.819 4 Ni100 -0.09836 -0.1921 -0.29042 -0.3864 -0.48112 -0.57674 -0.67966 -0.76811 -0.86531 2.696 4 Cu100 -0.10312 -0.19007 -0.299 -0.39392 -0.50628 -0.61128 -0.71152 -0.79512 -0.89624 2.971 6 Cu59 Zn41 (H59) -0.10505 -0.21154 -0.31712 -0.41582 -0.5155 -0.6313 -0.7299 -0.84279 -0.94332 2.935 2 FeCrNiMn(SS304) -0.10681 -0.21337 -0.3227 -0.42765 -0.53213 -0.62525 -0.73477 -0.84632 -0.95621 2.823 1 Al100 -0.25469 -0.51498 -0.77095 -1.02784 -1.28281 -1.54666 -1.79796 -2.06729 -2.31803 2.553 8