In Vitro Quantitative Evaluation of Postprocessing Filter for Metal Artifact Reduction in Cone Beam Computed Tomography Images of Titanium and Zirconium Dioxide Implants
Table 2
Comparison between filters/teeth for titanium and zirconium dioxide implant.
Titanium implant
Zirconium dioxide
Filter
Median
Result
SD
Filter
Median
Result
SD
41
41
BAR
7.4
C
0.1
BAR
6.7
D
0.3
Multi-CDT NR
8.4
B
0.1
Multi-CDT NR
7.6
C
0.0
2x
9.1
AB
0.2
2x
9.2
B
0.0
1x
9.2
AB
0.1
1x
9.3
B
0.2
Nonfiltered
9.5
A
0.2
Nonfiltered
9.8
A
0.1
43
43
BAR
5.7
D
0.0
BAR
7.4
D
0.1
Multi-CDT NR
6.0
CD
0.0
Multi-CDT NR
8.4
C
0.1
2x
6.3
BC
0.2
2x
9.1
B
0.1
1x
6.4
AB
0.3
1x
9.2
AB
0.0
Nonfiltered
6.7
A
0.0
Nonfiltered
9.5
A
0.0
44
44
BAR
6.7
B
0.0
BAR
7.2
C
0.1
Multi-CDT NR
7.6
B
0.1
Multi-CDT NR
8.4
B
0.2
2x
9.2
A
0.2
2x
8.9
A
0.2
Nonfiltered
9.3
A
0.1
Nonfiltered
9.1
A
0.0
1x
9.8
A
0.2
1x
9.2
A
0.2
46
46
BAR
5.1
D
0.1
BAR
6.6
C
0.2
Multi-CDT NR
5.9
C
0.1
Multi-CDT NR
7.2
B
0.1
2x
6.0
BC
0.2
2x
8.8
A
0.0
Nonfiltered
6.2
AB
0.1
1x
8.9
A
0.0
1x
6.4
A
0.3
Nonfiltered
9.1
A
0.2
Medians followed by the same letters do not differ significantly from each other.