Research Article

[Retracted] Improvement of the Accuracy in the Identification of Coronary Artery Disease Combining Heart Sound Features

Table 2

The relationship between heart sound characteristics and CAD or non-CAD.

No.SourceRecordings (V2·s) (V2·s)M1 (Hz)T1 (Hz)P3Is it CAD?Note

1SCDB40 cardiac cycles28619.3Yes50% coronary blockage
2SCDB40 cardiac cycles19425.14Yes60% coronary blockage
3MHSDB40 cardiac cycles391016.19NoNormal
4SCDB40 cardiac cycles22810.17Yes90% coronary blockage
5SCDB40 cardiac cycles27662.46YesMultiple coronary blockages
6SCDB40 cardiac cycles2348.96Yes50% coronary blockage
7SCDB40 cardiac cycles4669.98Yes90% coronary blockage
8MHSDB40 cardiac cycles47227.38NoMitral stenosis
9MHSDB40 cardiac cycles0051130.92NoLate diastolic valve murmurs
10SCDB40 cardiac cycles18448.16YesMultiple coronary blockages
11MHSDB40 cardiac cycles2170.86NoEarly and late valve diastolic murmurs
12SCDB40 cardiac cycles60211.35NoNormal