Research Article

Validated HPLC-UV Method for Simultaneous Estimation of Paclitaxel and Doxorubicin Employing Ion Pair Chromatography: Application in Formulation Development and Pharmacokinetic Studies

Table 4

Robustness expressed in percent mean recovery and percent relative standard deviation for PTX and DOX.

ParameterRtRecovery (%)%RSD

PTX
 Mobile-phase ACN : water (68 : 32)3.6799.820.138
 Mobile-phase ACN : water (63 : 37)4.4198.201.318
 Mobile-phase ACN : water (58 : 42)5.6098.770.906
 Flow rate (0.9 ml/min)4.86102.461.804
 Flow rate (1.0 ml/min)4.3897.771.638
 Flow rate (1.1 ml/min)3.9999.440.413
 Column temp. (40°C)4.3698.301.256
 Column temp. (35°C)4.3997.501.818
 Column temp. (30°C)4.4099.030.679
DOX
 Mobile phase (68 : 32)7.53100.640.451
 Mobile phase (63 : 37)7.46101.050.744
 Mobile phase (58 : 42)7.2899.590.297
 Flow rate (0.9 ml/min)7.74100.340.240
 Flow rate (1.0 ml/min)7.48100.680.485
 Flow rate (1.1 ml/min)6.3599.070.660
 Column temp. (40°C)6.95100.980.698
 Column temp. (35°C)7.34100.850.603
 Column temp. (30°C)7.39101.641.154