Research Article
[Retracted] Clinical Outcomes of Treatment Strategies for Postoperative Plate Fracture and In Situ Fracture of the Femoral Shaft
Table 1
Basic information characteristics of included patients.
| Case no. | Gender | Age | Cause of breakage | Fracture callus tissue grading | Adverse events | Supply area complications | Fracture healing time | Revision fixation |
| 1 | Male | 39 | High screw density | I | None | None | 9 | Yes | 2 | Male | 21 | Medial bone defect | II | None | None | 6 | Yes | 3 | Female | 50 | Premature weight bearing | II | None | None | 8 | Yes | 4 | Female | 65 | Premature weight bearing | III | None | None | 5 | No | 5 | Female | 53 | High screw density | III | Superficial infection | None | 5 | No | 6 | Male | 35 | Inappropriate exercise | II | None | None | 6 | Yes | 7 | Female | 72 | Delayed healing | II | None | Numbness in the anterior lateral femur | 7 | Yes | 8 | Male | 58 | Poorly repositioned medial bone mass | III | None | None | 7 | No | 9 | Male | 62 | High screw density | II | None | None | 8 | Yes | 10 | Male | 25 | Retrauma | V | None | None | 5 | No | 11 | Male | 39 | Retrauma | IV | None | None | 4 | No | 12 | Female | 50 | Improper application of steel cables | IV | None | None | 4 | No | 13 | Female | 36 | Delayed healing | II | None | None | 6 | Yes | 14 | Male | 20 | High screw density | III | None | None | 5 | No | 15 | Female | 74 | Poorly repositioned medial bone mass | I | None | Intractable pain | 8 | Yes | 16 | Male | 54 | Premature weight bearing | III | None | None | 8 | No | 17 | Male | 62 | Inappropriate exercise | III | None | None | 6 | No | 18 | Female | 37 | Improper application of steel plates | II | None | None | 6 | Yes | 19 | Male | 56 | Retrauma | IV | None | None | 5 | No | 20 | Male | 45 | Premature weight bearing | III | Superficial infections | None | 7 | No | 21 | Male | 51 | Delayed healing | III | None | None | 11 | No | 22 | Female | 56 | Improper application of steel cables | I | None | None | 6 | Yes | 23 | Male | 38 | Improper application of steel cables | I | None | None | 8 | Yes | 24 | Male | 57 | Medial bone defect | IV | None | None | 4 | No | 25 | Female | 26 | Premature weight bearing | III | None | None | 5 | No | 26 | Female | 55 | Improper application of steel plates | I | None | None | 7 | Yes | 27 | Male | 27 | Improper application of steel plates | I | None | Fat liquefaction and infection | 6 | Yes | 28 | Male | 52 | Delayed healing | III | None | None | 9 | No | 29 | Female | 54 | Poorly repositioned medial bone mass | II | None | None | 6 | Yes | 30 | Female | 65 | Medial bone defect | IV | None | None | 4 | No | 31 | Male | 32 | Delayed healing | III | None | None | 5 | No | 32 | Male | 51 | High screw density | I | None | Contact dermatitis | 5 | Yes | 33 | Male | 41 | High screw density | III | None | None | 6 | No |
|
|