Research Article

[Retracted] Optimized IANSegNet: Deep Segmentation for the Detection of Inferior Alveolar Nerve Canal

Table 2

Performance comparison of IANSegNet with diverse loss functions.

LossPostprocessingDice (%)Sensitivity (%)Hausdorff (mm)
DPVVPMDPPMVVDPPMVV

Cross-entropyYes79.8884.6091.1282.3290.6684.752.874.467.27
DiceYes81.2186.1190.7182.2591.3384.662.883.926.75
FusionYes83.5992.1888.7085.2091.3985.592.513.716.60
Cross-entropyNo75.4984.1891.1281.5790.6682.613.694.467.27
DiceNo79.0585.8090.7182.3391.3383.332.873.926.80
FusionNo77.5885.8591.2184.8991.3982.773.803.886.90