Research Article
Impact of Quality Improvement Bundle on Compliance with Resuscitation Guidelines during In-Hospital Cardiac Arrest in Children
Figure 3
(a) Data-driven debriefing of CPR event using data from central monitor and defibrillation. (b) Code Stat® dashboard displaying our team’s performance related to chest compression quality metrics during a CPR event. (c and d) Code Stat® records of chest compression quality in a patient showing timing of the first chest compression in relation to timing of the onset of cardiac arrest and chest compression interruption during CPR, respectively.
| (a) |
| (b) |
| (c) |
| (d) |