Research Article

Facing High EEG Signals Variability during Classification Using Fractal Dimension and Different Cutoff Frequencies

Table 6

Cutoff frequencies selected for each subject for Condition B.

SubjectHiguchiKatzAR

A19–2918–282–82
A29–3925–454–84
A38–487–178–48
A414–2414–24112–122
A55–3527–3716–36
A68–6810–904–34
A73–236–163–23
A87–1076–161–41
A926–369–192–12