Research Article

SSVEP Enhancement Using Moving Average Filter Controlled by Phase Features

Table 2

Average accuracy among the five subjects (in %).

MethodSubject 1Subject 2Subject 3Subject 4Subject 5Average

Standard CCA9081.665071.6691.6677
Proposed method92.8683.9364.2987.592.8684.29
CSP96.6776.6756.6766.679578.33
PLS93.3356.675586.6798.3378
MEC91.6781.6748.337086.6775.67
CAR91.6771.675066.679074
AMUSE9078.334561.6788.3372.67
SOBI-AF391.6773.3351.676588.3374
SOBI-OZ88.3370506586.6772
SOBI-FFT88.3371.6756.6768.3391.6775.33
Infomax-AF3907546.6771.679074.67
Infomax-OZ9073.3348.33709073.33
Infomax-FFT93.3378.3351.6771.6791.6777.33
JADE-AF388.3376.6746.6773.3391.6775.33
JADE-OZ88.3370506586.6772
JADE-FFT9073.3353.3366.679074.67