Research Article

An Explainable Statistical Method for Seizure Prediction Using Brain Functional Connectivity from EEG

Table 2

Seizures prediction results for the patients in FH-PKU database via our method.

Patient IDBN dataRaw dataBN + raw data
AUCSENSFDRAUCSENSFDRAUCSENSFDR

2000020.9501000.1250.63740.00.0250.94580.00.000
2104160.99195.00.0260.9451000.1840.98395.00.053
2104430.95790.00.0000.72670.00.3590.96790.00.000
2104470.90089.50.2370.74978.90.3420.86594.70.316
2104540.89185.00.1050.8341000.4470.93090.00.132
2104600.9961000.0710.84790.00.2840.99596.70.035
2104650.99295.00.0350.79080.00.3190.9851000.113
2104670.93990.00.0290.79570.00.1430.96790.00.029
2104700.97590.00.0000.8201000.4470.97890.00.000
2104710.92980.00.0250.57950.00.2560.91085.00.154
2104770.97187.50.0260.65195.80.6920.92787.50.103
2104860.9951000.0250.86965.00.0260.98995.00.051
2104890.97890.00.0260.74985.00.3680.98890.00.026
2104941.0001000.0000.94992.90.1541.0001000.000
2104980.9921000.0280.61170.00.4510.9871000.056
2104990.94880.00.0130.73060.00.1970.9701000.158
2105030.87780.00.0400.9811000.0670.9861000.080
Average0.95891.30.0480.78079.30.2800.96393.10.077