Research Article

An Intelligent Identification and Repair Method for Annular Holes in 3D Printing

Table 1

Comparison of repair results after inspection.

ObjectsMethodsNonmanifold edgesSelf-intersectionsHighly creased edgesSpikesSmall componentsSmall holesRepair time (s)

ShoeGeomagic0102503453000.077
Method in this paper01139136000.086

BoneGeomagic000357000.056
Method in this paper0000000.062

ToothGeomagic090621398000.046