Research Article

Study on Spontaneous Combustion “Three Zones” of the Distribution Law and Integrated Fire Prevention Technology in Mined-Out Area of Lingquan Mine

Table 2

Range of measuring points for “three zones.”

Measuring pointHeat dissipation zoneOxidation zoneSuffocation zone

1#0–41.5 (m)41.5–95.6 (m)>95.6 (m)
2#0–40.8 (m)40.8–86.0 (m)>86.0 (m)
3#0–35.0 (m)35.0–79.6 (m)>79.6 (m)
4#0–25.0 (m)25.0–60.0 (m)>60.0 (m)
5#0–43.0 (m)43.0–72.0 (m)>72.0 (m)