Research Article

Development and Validation of Embedded Device for Electrocardiogram Arrhythmia Empowered with Transfer Learning

Table 7

Class-wise training and validation results of the proposed DVEEA-TL model.

TEvaluation matrixFNVQS
Fusion beat (%)Normal beat (%)Ventricular beat (%)Unknown beat (%)Supraventricular beat (%)

AccuracyTraining99.9199.9599.88100100
Validation99.8199.7899.82100100

Classification miss rateTraining0.090.050.1200
Validation0.190.220.1800

SensitivityTraining99.5699.74100100100
Validation98.90100100100100

SpecificityTraining19.7427.1325.0725.0728.19
Validation20.0334.9323.6925.3728.55

PrecisionTraining99.8910054.70100100
Validation10010099.04100100

FPRTraining0.800.730.750.750.72
Validation0.800.650.760.750.71

FNRTraining0.0040.002000.004
Validation0.010000