Research Article
[Retracted] Fuzzy Algorithm Based Bionic Optimization Design of Boring Machine Column
Table 2
Summary of topology optimization data results.
| Performance parameter | Column prototype | Topology optimization column | Optimization change rate (%) |
| Maximum stress (MPa) | 5.434 | 3.864 | −28.9% | Maximum deformation (mm) | 0.162 | 0.126 | −22.1% | Overall quality (kg) | 87061 | 82107 | −5.7% | First order mode (Hz) | 21.6 | 23.96 | +10.9% | Second order mode (Hz) | 22.37 | 25.93 | +15.9% | Third order mode (Hz) | 35.81 | 47.7 | +33.2% | Fourth order mode (Hz) | 54.12 | 57.23 | +5.75% | Fifth order mode (Hz) | 61.64 | 62.03 | +0.6 | Sixth order mode (Hz) | 63.17 | 70.96 | +12.3% | Specific strength (N⋅m/kg) | 0.00275 | 0.0041 | +48.4% | Specific stiffness [MPa/(kg⋅mm)] | 0.92 | 1.255 | +36.4% |
|
|