Research Article

Epilepsy Detection Based on Variational Mode Decomposition and Improved Sample Entropy

Table 7

Epilepsy detection performance (100%).

 AccuracySensitivitySpecificityNumber of channelNoisy

Reference [20]85.691.780.618No
Reference [21]91.0987.8394.3518No
Reference [22]95.0097.5095.0018No
Reference [23]95.7198.6584.1523No
Reference [24]99.0595.4599.105No
Reference [25]99.610099.823No
Reference [26]99.6397.8499.635No
Reference [27]99.6699.7299.608No
Reference [28]72.1074.7869.341No
Reference [29]75.2150.9687.371No
Reference [30]92.1387.1094.651No
Reference [31]92.7993.0794.841No
Proposed method91.7891.2793.612Yes