Research Article
Shafting Misalignment Malfunction Quantitative Diagnosis Based on Speed Signal SVD-HT and CSF-PPSO-ESN Method
Table 4
Three groups of verification—repeating experimental data of angular misalignment.
| Standard angular misalignment (°) | The misaligned malfunction diagnosis results using the CSF-PPSO-ESN method (°) | The misaligned malfunction diagnosis results using the order spectrum analysis and RBF neural network (°) | Group one | Group two | Group three | Group one | Group two | Group three |
| 0.001 | 0.004 | 0.008 | 0.002 | 0.043 | 0.015 | 0.007 | 0.252 | 0.254 | 0.249 | 0.253 | 0.272 | 0.241 | 0.218 | 0.501 | 0.507 | 0.498 | 0.497 | 0.452 | 0.476 | 0.517 | 0.749 | 0.749 | 0.748 | 0.752 | 0.747 | 0.789 | 0.715 | 1.000 | 0.997 | 1.002 | 0.996 | 0.987 | 1.038 | 0.963 | 1.251 | 1.249 | 1.252 | 1.255 | 1.221 | 1.253 | 1.272 | 1.499 | 1.502 | 1.498 | 1.503 | 1.537 | 1.506 | 1.468 | 1.751 | 1.748 | 1.751 | 1.754 | 1.784 | 1.716 | 1.749 | 2.000 | 2.003 | 1.997 | 2.002 | 2.028 | 2.008 | 1.974 |
|
|